One Room Colder Than the Rest of the House? Causes and Fixes
One room always colder than the rest of the house? Blocked vents, duct leaks, missing insulation and drafts are the usual causes. Here are 9 fixes, cheapest first.
6 min read
Free tool
Enter your room size, ceiling height and insulation to see the space heater wattage you need, in watts and BTU, and how many 1,500 W heaters it takes.
Watts needed = floor area × 10 watts × (ceiling height ÷ 8), then adjusted:
| Condition | Adjustment |
|---|---|
| Good insulation | Multiply by 0.8 |
| Average insulation | No change |
| Poor insulation or drafts | Multiply by 1.25 |
| Over a garage, north side or lots of glass | Multiply by 1.2 |
One watt gives off about 3.412 BTU per hour, which is how the BTU figure is worked out. This is a rule of thumb. The best fix for a room that will not warm up is often to find out why, as described in one room colder than the rest of the house.
A common rule is about 10 watts per square foot for a room with an 8 foot ceiling and average insulation. A 12 by 12 foot room (144 sq ft) needs about 1,440 watts, so a 1,500 W heater fits.
Roughly 150 square feet in an average room. A poorly insulated room, a high ceiling or a cold location cuts that figure.
No. Most plug-in heaters top out at 1,500 watts because that is what a standard 15 amp circuit can safely carry. A heater that is too big for the room cycles on and off, and one that is too small never catches up.
Only on separate circuits. Two 1,500 W heaters on the same circuit will usually trip the breaker, and can overheat the wiring if the breaker fails.

Home Problems
One room always colder than the rest of the house? Blocked vents, duct leaks, missing insulation and drafts are the usual causes. Here are 9 fixes, cheapest first.
6 min read

Home Problems
Space heater tripping the breaker? An overloaded circuit is the usual cause. Check what else shares the circuit, try the low setting and know when it's a fault.
3 min read
Most rooms are 8 ft.
Room size
144 sq ft
Heater power needed
1,450 W
In BTU per hour
4,900
1,500 W heaters
1
Formula: area × 10 watts × (ceiling height ÷ 8), adjusted for insulation and location. This is a rule of thumb, not an engineering calculation. A standard 1,500 W plug-in heater covers roughly 150 sq ft in an average room.